Constructional Features of Gas Turbine Plant Points : Constructional Features of Gas Turbine Plant , Function of main components, High Pressure Compressor, Heat Exchanger, Combustion Chamber, H.P Turbine, L.P TurbineFunction of Main Components Air FilterThe function of air filter is to filter clean the air draw by the atmosphere.Low Pressure CompressorThe function of L.P compressor is to compress the air coming from the air
filter.Inter CoolerThe compressed air which is coming from L.P compressor enters inter-cooler where it
cool down it temp.High Pressure CompressorThe compressed air coming from inter cooler enters in to H.P compressor where its completely
compressed under high pressure.Heat ExchangerThe function of heat exchanger is to change the cooled compressed air’s temp completely in to hot air.Combustion ChamberThe main component of gas turbine is combustion chamber where the hot air is mixed. In combustion
chamber the combustion of fuel takes place and his combusted fuel is mixed with hot air and this
made the combustion product.H.P TurbineThe turbine is also a main component of gas turbine where the product of combustion expanded and it
give or it convert in to K.E and gives mechanical work.L.P TurbineThe Hot gases alter given full efficiency to the high pressure turbine it flows to the low pressure turbine
the hotness the gas is low down and it gives their low mechanical work.