- Acetylene valve decrease the inlet pressure of utmost of on 18kg/square cm to torch pressure of not more than 0.8kg per square cm. A 30 kg per square cm is attached to high pressure side and a gauge 8.5kg/square cm is close to the low pressure side.
- Oxygen valve decrease the cylinder pressure as of 150kg/square cm depending ahead the torch and size of tip. A 220 kg/square cm gauge is close to high pressure side and a gauge reading up to 11 kg per square cm or less is close to the low pressure side.
- To preserve a stable pressure at the torch-tip despite of any difference that may take put in the source.
- Decrease the Inlet pressure as of generator, cylinder or manifold to that, necessary at the blow pipe.
- To regulate the delivery at the preferred pressure inside its range.