Refrigeration and Air Conditioning - Multiple Choice Questions
Points : mcqs, refrigeration and air conditioning multiple choice questions answers with answer key, refrigeration and air conditioning objective type question answers, absorption & refrigeration multiple choice questions answers, steam jet refrigeration system multiple choice questions answers, air washer multiple choice questions answers, screw compressor multiple choice questions answers, commercial air conditioning multiple choice questions answers, humidifiers and dehumidifier multiple choice questions answers, ice plants multiple choice questions answers
1. Steam jet refrigeration cycle employs a compressor device called.
a) vapor compressor
b) liquid pump
c) steam ejector
2. The load control in steam jet refrigeration cycle is obtained by
a) using multiple parallel ejector
b) increasing the mass flow rate of motive steam through nozzles
3. The cop of steam refrigeration cycle is of the order of.
a) 3 to4
b) 0.5 to 0.8
c) none of the above
- Home
- Lathe Machine
- Milling Machine
- Shaper Machine
- Planer Machine
- Slotter Machine
- Hydraulic Machines
- Boilers
- Wood Working Machines
- Work Holding Devices
- Wood Working Tools
- Gauges
- Measuring Tools
- Drilling Machines
- Saws
- Grinder
- Internal Combustion Engine
- Steam Engine
- Welding
- Safety Precautions
- Power Plant
- Gas Turbine Power Plant
- Casting Process
- Water and Steam Turbines
- Metallurgy
- Foundary
- Electronics
- Electrical
- Broaching, Boring Machine
- Auto & Diesel
- Objective
- Technical Theory
Search This Blog
Showing posts with label Refrigeration. Show all posts
Showing posts with label Refrigeration. Show all posts
Refrigeration and Air Conditioning - Fill in the Blanks
Refrigeration and Air Conditioning - Fill in the Blanks
Points : mcqs, refrigeration and air conditioning, refrigeration and air conditioning fill in the blanks with answer key, refrigeration and air conditioning objective type question answers, absorption & refrigeration fill in the blanks, steam jet refrigeration system fill in the blanks, air washer fill in the blanks, screw compressor fill in the blanks, commercial air conditioning fill in the blanks, humidifiers and dehumidifier fill in the blanks, ice plants fill in the blanks,
- Air washer has two types.
- Air washer is primarily employed in industrial air conditioning applications.
- The unitary spray air washer requires considerable less space than a central station type.
Refrigeration and Air Conditioning - True and False
Refrigeration and Air Conditioning - True and False
Points : Mcqs with answer key, Refrigeration and Air Conditioning, Refrigeration and Air Conditioning True and False with answer key, Refrigeration and Air Conditioning Objective Type Question Answers, Absorption & Refrigeration True and False, Steam Jet Refrigeration System True and False, Air Washer True and False, Screw Compressor True and False, Commercial Air Conditioning True and False, Humidifiers and Dehumidifier True and False, Ice Plants True and False,
- In a steam jet system closed chilled water is more efficient. False
- In a steam jet refrigeration system the steam supply should be free from suspended or dissolved solids carry over from the boiler otherwise the nozzle may plug. True
- A steam jet system is a vacuum refrigerant system. True
Advantages and Disadvantages of Steam Jet Refrigeration System
Advantages and Disadvantages of Steam Jet Refrigeration System
Points : advantages and disadvantages of steam jet refrigeration system
Advantages
- En sizes above 75 tonnes, the initial cast of steam jet system is competitive with vapour compression machines and operating cost is hardly 50% of the mechanical compression system.
Advantages and Disadvantages of Thermoelectric Refrigeration System
Advantages and Disadvantages of Thermoelectric Refrigeration System
Points : advantages and disadvantages of thermoelectric refrigeration system
Advantages
- An interchange of heating and cooling process can be exercised just by reversing the polarity.
- The weight per unit refrigeration .is considerably lower than convention al refrigeration system.
Advantages and Disadvantages of Vortex-Tube Refrigeration System
Advantages and Disadvantages of Vortex-Tube Refrigeration System
Points : advantages and disadvantages of vortex-tube refrigeration system
Advantages
- There is no leakage problem as it uses only air as the refrigerant.
- Initial cost is low. At places where compressed air is readily available, its working expanses are also low.
- Requires less space.
Advantages and Disadvantages of Mixed Refrigerant System
Advantages and Disadvantages of Mixed Refrigerant System
Points : advantages and disadvantages of mixed refrigerant system
Advantages
- Evaporation temperature variation at, a given refrigerating effect or refrigerating effect variations at a given evaporation temperature is feasible.
- It is possible to reduce condenser pressure by addition of higher boiling point refrigerant.
Advantages and Disadvantages of Cascade Refrigeration System
Advantages and Disadvantages of Cascade Refrigeration System
Points : advantages and disadvantages of cascade refrigeration system
Advantages
- It also reduces the lubricating problems since the lubricant associated with each, refrigerant has to withstand a temperature range not more than 60°C whereas in multistage system, the lubricant can have to be working over temperature range of order of 105°C.
Subscribe to:
Posts (Atom)