Function of Main Components
Air Filter
The function of air filter is to filter clean the air draw by the atmosphere.
Low Pressure Compressor
The function of L.P compressor is to compress the air coming from the air
filter.
Inter Cooler
The compressed air which is coming from L.P compressor enters inter-cooler where it
cool down it temp.
High Pressure Compressor
The compressed air coming from inter cooler enters in to H.P compressor where its completely
compressed under high pressure.
Heat Exchanger
The function of heat exchanger is to change the cooled compressed air’s temp completely in to hot air.
Combustion Chamber
The main component of gas turbine is combustion chamber where the hot air is mixed. In combustion
chamber the combustion of fuel takes place and his combusted fuel is mixed with hot air and this
made the combustion product.
H.P Turbine
The turbine is also a main component of gas turbine where the product of combustion expanded and it
give or it convert in to K.E and gives mechanical work.
L.P Turbine
The Hot gases alter given full efficiency to the high pressure turbine it flows to the low pressure turbine
the hotness the gas is low down and it gives their low mechanical work.