Constructional Features of Gas Turbine Plant

Constructional Features of Gas Turbine Plant Points : Constructional Features of Gas Turbine Plant , Function of main components, High Pressure Compressor, Heat Exchanger, Combustion Chamber, H.P Turbine, L.P Turbine Function of Main Components Air Filter The function of air filter is to filter clean the air draw by the atmosphere. Low Pressure Compressor The function of L.P compressor is to compress the air coming from the air filter. Inter Cooler The compressed air which is coming from L.P compressor enters inter-cooler where it cool down it temp. High Pressure Compressor The compressed air coming from inter cooler enters in to H.P compressor where its completely compressed under high pressure. Heat Exchanger The function of heat exchanger is to change the cooled compressed air’s temp completely in to hot air. Combustion Chamber The main component of gas turbine is combustion chamber where the hot air is mixed. In combustion chamber the combustion of fuel takes place and his combusted fuel is mixed with hot air and this made the combustion product. H.P Turbine The turbine is also a main component of gas turbine where the product of combustion expanded and it give or it convert in to K.E and gives mechanical work. L.P Turbine The Hot gases alter given full efficiency to the high pressure turbine it flows to the low pressure turbine the hotness the gas is low down and it gives their low mechanical work.