Working of La Mont Boiler
Working of La Mont Boiler
Points : Working of La Mont Boiler
Feed water as of hot well is supply to a storage and separating drum through economizer. The majority of
sensible heat is supplied to feed water passing through economizer. A centrifugal pump flow the water equal
to 8 to 10 ties weight of steam evaporated. This water is circulated through evaporator tubes and part of
water evaporated is separated in separator drum. The large amount of water circulated prevents the tubes as
of being overheated. Centrifugal pump deliver the feed water to headers at pressure of 2.5 bars above drum
pressure. The distribution header distributes water through the nozzle into evaporator. Steam divided in
the boiler is extra passed through the superheater and then supplied to turbine. The air drawn through the
blower is preheated in air preheater through the flue gases before these are discharged through chimney.
The heated air from air preheater is supplied to combustion chamber and it improves the combustion
efficiency.