Layout of Modern Steam Power Plant
Points : Layout of Modern Steam Power Plant, Cooling Water Circuit, Feed Water and Steam Flow Circuit, Feed Water and Steam Flow Circuit, Coal and Ash Circuit
Steam power plant has to contain following equipments:
General layout of thermal power plant consists of mostly 4 circuits. The four
major circuits are:
1. Cooling Water Circuit
2. Feed Water and Steam Flow Circuit
3. Air and Gas Circuit
4. Coal and Ash Circuit
1. Cooling Water Circuit
This circuit has of cooling tower, cooling water pumps and circulating water
pump,. The amount of cooling water requisite to condense the steam is
significantly large with it is taken as of lake, sea or river. Cooling water
is in use as of the upper side of river, it is passed throughout the condenser
with heated water is discharge to lower side of river. Such method of cooling
water supply is feasible if sufficient cooling water is accessible through the
year. This method is identified as open system. As the sufficient water is not
accessible, then the water imminent out as of the condenser is chilled also in
cooling pond or cooling tower. Cooling is effect by fairly evaporate the
water. This evaporative failure (this includes evaporation with put back) is
almost 2 to 5 % of cooling water circulated in system. To recompense the
evaporative loss, water as of the river is constantly supplied. As the cooling
water coming out of condenser is cooled over with supplied to condenser, then
the system is identified as closed system. As the water coming out as of
condenser is discharge to river downward side frankly, the system is
identified as open system. Open system is inexpensive than closed system
provide sufficient water is accessible during year.
2. Feed water and Steam Flow Circuit
This circuit has of, feed heaters, boiler, turbine and boiler feed pump. Steam
produce in boiler is fed to steam prime mover to increase the power. Steam
coming out of prime mover is reduced in the condenser and then fed to boiler
by the help of pump. Condensate is heated in feed heaters using the steam
tapped as of different points of turbine. Feed heaters might be of mix kind or
indirect heating form. Various of steam and water is lost passing through
unusual components of system, thus, feed water is supplied as of external
cause to balance this loss. Feed water supplied as of external cause is passed
through the purifying plant to decrease the dissolve salts to a suitable
level. The purification is required to shun the scaling of boiler tubes.
3. Air and Gas Circuit
This circuit has of air pre-heater, air filter, dust collector and chimney.
Air is in use in as of the atmosphere to air preheater throughout the action
of a enforced or induce draught fan or with using both. Dust as of the air is
detached by means of using air filter previous to deliver to combustion
chamber. Exhaust gases moving enough quantity of heat with ash are passed
during air preheater where exhaust heat of gases is specified to air and then
it is accepted through dust collectors where mainly of dust is detached before
exhausting gases to atmosphere throughout chimney.
4. Coal and Ash Circuit
This circuit has of ash storage, coal storage, coal handling and ash handling
systems. Handling system consists of screw conveyors, belt conveyors and so
on. Coal arrives at storage yard with after required handling, pass on to
furnaces throughout the fuel feeding mechanism. Ash ensuing as of combustion
of coal collect at back of boiler with is detached to ash storage yard during
ash handling tools.